Tita-prosthesis type Partial Vario Campana
Tita-prosthesis type Partial Vario Campana is used for partial ossicular chain reconstruction. It is a Malleus and Incus replacement which connects the Tympanic Membrane to the head of the Stapes. It consists of a Head Plate (Disk) Shaft, and Campana type cup.
Material : Titanium Medical Gr 2 ( ASTM F 67 )
Design Benefits
-
Only one Tita-prosthesis type partial Vario Campana
is required as a
partial prosthesis.
-
MRI Compatible.
-
Enhanced viewing capability during implantation because of
four
symmetrical bore holes on disk.
-
Offers best possible length selection.
-
Low risk of dislocation because of Campana shaped cup.
-
Radial outer facing of disk minimizes risk of tympanic
membrane injury.
-
Partially roughened surface on upper part of disk and
inside
cup stabilizes prosthesis placement.
Shaft Diameter – 0.3 mm
L (Functional Length) – 1.75 mm to 5.00 mm
REF
Number |
Description |
No. of
Piece/Package |
E1101 |
Tita-prosthesis type Partial Vario Campana with
removable head, and it can be trimmed from 5.00
mm to 1.75 mm using Osseous Cutter
(REF: EI01) |
1 piece, Gamma
Sterile
|
|
 |
|
Tita-prosthesis type Total Vario Cask
Tita-prosthesis type Total Vario Cask is used for total ossicular chain reconstruction. It is a Total Ossicular chain replacement prostheses which connects the Tympanic Membrane and Footplate of the stapes (At the Oval Window). It consists of a Head Plate (Disk), Shaft, and Cask type cup.
Material : Titanium Medical Gr 2 ( ASTM F 67 )
Design Benefits
REF Number |
Description |
No. of Piece/Package |
E1102 |
Tita-prosthesis type Total Vario Cask with
removable head, It can be trimmed from 7.00 mm
to 3.00 mm using OSSEOUS CUTTER (REF: EI01) |
1 piece, Gamma
Sterile
|
|
 |
|
Tita-prosthesis Piston type Loop
Tita-prosthesis Piston type Loop is used
for Stapedioplasty surgery. It is
connected between Long process of Incus (or
Malleus — Stapedioplasty)
and Oval
window. It consists Loop
(Flat Band) and Piston.
Material : Titanium Medical Gr 2 ( ASTM F 67 )
Design
Benefits
-
Only one Tita-prosthesis piston type loop
prosthesis is required in
Stapedioplasty Surgery.
-
Stable design provides maximum sound output.
-
Offers best possible length selection.
-
Easy loop introduction.
-
Reduced risk of osteo-necrosis.
-
Atraumatic design.
- MRI Compatible.
Shaft Diameter – 0.4 mm
Loop Shaft Diameter – 0.2 mm
L (Functional Length) – 3.50 mm
to 7.00 mm
REF Number |
Description |
No. of Piece/Package |
E1103 |
Tita-prosthesis
Piston type Loop, It can be trimmed from 7.00
mm to 3.50 mm using Osseous Cutter (REF: EI01) |
1 piece, Gamma
Sterile
|
|
 |
|
INSTRUMENTS
INSTRUMENTATION FOR MIDDLE EAR IMPLANTS
OSSEOUS CUTTER
OSSEOUS CUTTER is used to cut the OSSEOUS
Titanium Middle Ear Prosthesis.
-
Tita-prosthesis type Partial Vario Campana.
-
Tita-prosthesis type Total Vario Cask.
-
Tita-prosthesis Piston Type Loop.
Osseous Cutter enables cutting of prostheses as per
required
length measured using Osseous Meter.
REF
Number |
Description |
No. of
Piece/Package |
EI01 |
OSSEOUS CUTTER |
1 piece
|
|
|
 |
|
OSSEOUS SIZER
OSSEOUS SIZER is used to measure the distance
between two points
in Partial and Total ossicular chain
reconstruction surgery.
REF
Number |
Description |
No. of
Piece/Package |
EI02 |
OSSEOUS SIZER |